These free 12×16 shed plans are for a 12 ft x 16 ft gable-roof storage shed with 2×4 walls, a floor on treated skids, a 72-inch (6-ft) double door in the long wall, two windows, and a 6-in-12 roof. You get a material list, step-by-step instructions, nine of our own drawings, and a free PDF with the full cut list. Every structural member is sized from a published table, and we show which one, so you or your building department can check the work.
Searching for “16×12 shed plans”? It’s the same footprint. At 192 sq ft, it’s the size on our site most likely to need a permit, so read that section first.
Check your local code first. Your city or county building department, not this plan, sets permit rules, setbacks, height limits, snow and wind loads, and frost depth. Check with them before you buy materials.
Free printable plan (PDF). No email required.
One printable file with the materials list, the full cut list, key steps, and all nine diagrams.

In this plan
Plain-language safety note: This design isn’t engineered or load-tested. No engineer has reviewed it, and we haven’t load-tested a shed built from it. The sizing comes from the 2024 International Residential Code (IRC) tables and manufacturer instructions, using the design conditions stated below. Your local building department sets the permit rules, snow and wind loads, and frost depth where you live. Confirm them before you build, and resize the framing if your loads are higher than the ones used here.
Want something smaller? See our 10×12, 8×10, and 4×8 lean-to plans, or compare free shed plans by size.
What you’re building: the 12×16 design at a glance
A gable roof sheds rain and snow both ways and gives the most headroom down the middle. The ridge runs the 16-ft length, and the 6-ft doors are centered in a 16-ft eave wall.
| Item | Size |
|---|---|
| Floor (outside of framing) | 144 in. x 192 in. (12 ft x 16 ft) |
| Walls | 2×4 studs at 16 in. on center (gable walls 12 in.), 89-3/4 in. tall with plates |
| Roof | Gable, 6-in-12 slope; ridge runs the 16-ft length |
| Rafters | 2×6 at 16 in. on center, 12 in. eave overhangs, flush gable ends |
| Ceiling joists (rafter ties) | 2×6 at 16 in. on center, beside each rafter |
| Ridge | 2×8 ridge board; 1×4 collar ties just under it |
| Door | 72 x 77-1/2 in. rough opening in the front wall under a 2-2×10 header, two 36-7/8 x 80 in. Z-frame leaves |
| Windows | Two 24 x 24 in. rough openings in the back wall |
| Floor | 2×6 joists at 16 in. on center on three 2-ply 2×8 skids, 23/32 in. tongue-and-groove deck |
| Siding | 4×8 engineered wood panel siding, 96 in. tall on the walls |
| Height | About 129-3/4 in. from the floor deck to the top of the ridge framing; about 12.0 ft from the bottom of the skids to the top of the roof |
All dimensions use actual lumber sizes: 2×4 = 1-1/2 x 3-1/2 in.; 2×6 = 1-1/2 x 5-1/2 in.; 2×8 = 1-1/2 x 7-1/4 in.; 2×10 = 1-1/2 x 9-1/4 in.; 1×4 = 3/4 x 3-1/2 in.
Why the walls are 89-3/4 in. tall: with the 6-1/4 in. floor frame, the siding runs exactly 96 in. from the bottom of the rim to the top of the wall, so one 8-ft panel covers it. Measure your siding panels before you frame: if they’re even slightly under 96 in., plan a joint at the top or buy 9-ft panels.
Full-length parts: the rims, plates, skids, and ridge are cut at the full 192 in., and the ceiling joists at 144 in. Pick boards that measure at least that long.
Who it suits: someone who has framed a deck or a small shed and has two helpers for raising the 16-ft walls and ridge. Plan on several weekends (our estimate).
Tools: circular saw, drill/driver, framing hammer, speed and framing squares, chalk line, 4-ft level, jigsaw, tin snips, two stepladders, and safety glasses, hearing protection, gloves, and a dust mask.
What fits in a 12×16 shed
Room for a riding mower or garden tractor, bikes, a workbench, and shelving on 192 sq ft. Measure your machine against the 72 x 77-1/2 in. door opening, and see the floor-load note below.
Do you need a permit for a 12×16 shed?
A 12×16 shed has a floor area of 192 square feet. That’s between the two model-code lines:
- The 2024 IRC, Section R105.2, exempts “one-story detached accessory structures, provided that the floor area does not exceed 200 square feet” from a building permit.
- The 2024 International Building Code (IBC), Section 105.2, exempts “tool and storage sheds, playhouses and similar uses” where the floor area is not greater than 120 square feet.
So it probably needs a permit where the IBC line or a local limit applies, and maybe not under the IRC line. Measured at the roof line (with the 12 in. eave overhangs), it covers 224 sq ft, which is over 200. Ask your building department whether you need a permit, how they measure, the setbacks, the height limit (this shed is about 12.0 ft tall, right at some local limits), and what foundation they accept. Zoning and HOA rules apply even without a permit, and the IRC says an exemption doesn’t authorize work that violates the code.
Also get your ground snow load, design wind speed, and frost depth (IRC Table R301.2, filled in locally); the checks below use them. In the US, call 811 before you dig or drive anchors.
Site and foundation for a 12×16 shed
Pick a level, well-drained spot with room to open both doors and walk around the shed.
Option 1: gravel pad with treated skids on solid blocks (used in this plan)
- Mark a pad 12 in. larger than the shed on every side (about 14 x 18 ft), the margin Suncast’s foundation guide uses. Suncast says to excavate, usually 4 to 6 in. (check local code), then fill with crushed gravel and compact it.
- Set solid (not hollow) concrete blocks in three rows of 6 under the future skid lines, about 36-3/4 in. apart center to center, with one under each end of each skid. Use solid blocks at least 8 x 16 in., and set each block on a 16 x 16 in. (or larger) concrete pad or paver over the compacted gravel; this plan requires the pads, because the 12×16 floor and roof put a lot of weight on each block. Check soil and footing rules with your building department: IRC Table R401.4.1 presumes 2,000 psf for clay and silt and 3,000 psf for sand and gravel, and soil below 1,500 psf needs a soils investigation.
- Set the skids on the blocks, level and parallel, 70-1/2 in. apart center to center.
- LP’s siding instructions require at least 6 in. between the siding and the grade. The siding starts at the bottom of the rim, on top of the 7-1/4 in. skids, so it clears 6 in. if the block tops are at or above grade. Shim only with treated or composite shims.
Option 2: concrete slab (or piers)
Footings below the frost line or a slab may be required locally (IRC R403). They need their own design, not included here.
Frost protection: check locally. The model 2024 IRC doesn’t require frost protection for a shed like this one. Section R403.1.4.1, Exception 1, says: “Protection of free-standing accessory structures with an area of 600 square feet (56 m2) or less, of light-frame construction, with an eave height of 10 feet (3048 mm) or less shall not be required.” This shed qualifies, with its eaves about 8-1/2 ft above grade. Your city or county can amend that rule and require footings, so ask.
Anchoring. Install at least one ground anchor at each corner, tied to the floor frame with the anchor maker’s hardware. American Earth Anchors shows corners plus side midpoints as one layout, which suits a 16-ft shed. Minute Man Products’ own guidelines say that where codes require anchoring to 90 mph wind standards, anchors should be at least 30 in. long with a tested holding capacity of at least 3,000 lb. Those are manufacturer recommendations, not IRC values (the IRC has no shed-anchor table), so ask your building department.

How every structural member was sized
Each member lists its design condition and source table, so you can check it against your local loads.
Design conditions used throughout
- Ground snow load: up to 70 psf (the highest column in the IRC rafter and header tables); roof live load 20 psf.
- Wind: ultimate design wind speed below 140 mph in Exposure B or below 130 mph in Exposure C. (the range for the king studs in IRC Table R602.7.5; uplift table R802.11 covers up to 140 mph).
- Lumber: No. 2 grade Douglas fir-larch, hem-fir, Southern pine, or spruce-pine-fir (check the grade stamp). Treated lumber for the skids and floor.
- Building width 12 ft; framing at 16 in. on center (gable walls 12 in.).
If your loads are higher, use the AWC Span Options Calculator or ask your building department.
| Member | Size used | Design condition and table | Allowed | This shed |
|---|---|---|---|---|
| Rafters | 2×6 No. 2 at 16 in. | IRC Table R802.4.1(7): 70 psf ground snow, 20 psf dead, ceiling not attached, L/180 | 7 ft 5 in. (SP) to 8 ft 1 in. (DF-L), horizontal | 71-1/4 in. (5 ft 11-1/4 in.) wall to ridge |
| Rafter overhang | 12 in. | IRC R802.7.1.1: notched cantilever | 24 in. max., 3-1/2 in. depth left at the birdsmouth | 12 in., about 3-15/16 in. left |
| Ridge board | 2×8 | IRC R802.3: 1 in. nominal min., at least as deep as the rafter’s cut end | 6-1/8 in. plumb cut needs more than a 2×6 | 7-1/4 in. |
| Ceiling joists (rafter ties) | 2×6 No. 2 at 16 in. | IRC Table R802.5.1(2): attic with limited storage, 20 psf live, L/240 | 12 ft 0 in. (SP) to 13 ft 0 in. (DF-L) | 137 in. (11 ft 5 in.) clear |
| Heel joints | 5-16d common | IRC Table R802.5.2(1): 5:12 row, 16 in. spacing, 12-ft span column | 3 / 3 / 4 / 5 nails at 20 / 30 / 50 / 70 psf | 5 nails |
| Collar ties | 1×4 at 16 in. | IRC R802.4.6: 1×4 min., 4 ft o.c. max., upper third of the attic space; Table R602.3(1) item 5 | 3-10d common each end | Bottom edge 29 in. above plates |
| Door header | 2-2×10 | IRC Table R602.7(1): roof and ceiling, 12-ft building width | 9-0 / 7-8 / 6-9 at 30 / 50 / 70 psf; 1 jack at 30 psf, 2 jacks at 50 and 70 psf | 6 ft 0 in. opening, 2 jacks each side |
| King studs at the door | 2 each side | IRC Table R602.7.5: 6-ft row; 2 king studs below 140 mph Exposure B or 130 mph Exposure C | 2 | 2 each side |
| Window headers | 2-2×6 | IRC Table R602.7(1), same column | 6-0 / 5-1 / 4-6 at 30 / 50 / 70 psf, 1 jack | 2 ft 0 in. openings, 1 king each side |
| Wall studs | 2×4 at 16 in. (12 in. in gable walls) | IRC Table R602.3(5): bearing wall, roof and ceiling only | 24 in. o.c., 10 ft height | 85-1/4 in. studs |
| Floor joists | 2×6 No. 2 at 16 in. | IRC Table R502.3.1(2): 40 psf live, 10 psf dead, L/360 | 9 ft 1 in. (HF) to 9 ft 9 in. (DF-L) | About 67-1/2 in. clear between skids |
| Skids | 2-ply 2×8 treated | IRC Table R507.5(1) deck beams: 40 psf live, 10 psf dead, wet service; 16-ft joist column (see notes) | IRC 2021: 5-4 (SP), 4-8 (DF-L/HF/SPF); IRC 2024: 6-5 (SP), 6-0 (DF-L/HF/SPF) | Blocks about 36-3/4 in. apart |
| Rafter-to-wall ties | Simpson H2.5A | Uplift demand: IRC Table R802.11 (see “Wind and uplift”). Tie capacity: Simpson catalog p. 277 (manufacturer rating, not a code value) | 615 lb (SPF/HF), manufacturer rating | 201 lb max. at 130 mph, Exposure C (the plan’s wind range); 247 lb at 140 mph C |
Notes on the table
- Why 2×6 rafters, not 2×4: a 2×4 at 16 in. is allowed only 5 ft 0 in. (SP) to 5 ft 6 in. (DF-L) at 70 psf, short of this roof’s 5 ft 11-1/4 in. span, and its birdsmouth wouldn’t leave the 3-1/2 in. depth R802.7.1.1 requires for an overhang.
- Ceiling joists are the closest check on this plan. The 2×6 ceiling joists span 11 ft 5 in. between the walls, against an allowed 12 ft 0 in. for Southern pine and more for the other species. That passes, but don’t swap in a lower grade than No. 2, and don’t load the attic beyond light storage.
- Why ceiling joists matter: IRC R802.2 requires continuous ties across the building so the rafters don’t push the walls apart. R802.5.2 accepts ceiling joists parallel to the rafters, in the bottom third of the rafter height, nailed per Table R802.5.2(1), and that lets the ridge be a plain board (R802.3).
- Heel nails: there’s no 6:12 row, so we used the 5:12 row (a lower slope pushes harder, so it needs more nails). Its footnote allows 10d common nails at 1.2 times the count, rounded up (6).
- Collar tie height: IRC R802.4.6 puts collar ties in the upper third of the attic space. With the bottom edge 29 in. above the plates, they’re in it whether you measure to the underside of the rafters at the ridge (the third starts about 22-5/8 in. up) or to the top of the ridge framing (about 26-5/8 in. up), and their top edge (32-1/2 in.) sits just under the ridge board. The ceiling joists stay in the bottom third (R802.5.2).
- Gable-end rafters sit on gable studs, with the ridge ends on 2×4 posts. Footnote b of Table R802.5.2(1) drops the heel joint connection where the ridge is supported by a load-bearing wall, header, or ridge beam, so the end pairs get no ceiling joists.
- Header table footnote: the 30 psf column also applies where the ground snow load is under 30 psf and the roof live load is 20 psf or less.
- Header bracing: Table R602.7(1) footnote f assumes the header’s top is braced by perpendicular framing. Here it sits tight under the top plate, which carries the rafters and joists. Don’t add cripples above it.
- Jacks and kings at the door: Table R602.7(1) calls for 2 jacks under each end of a 6-ft 2-2×10 header at 50 and 70 psf. Table R602.7.5 sets the number of full-height king studs at each end of a header: 2 for a 6-ft opening at the wind speeds above. The windows’ 2-ft openings need 1.
- Why a 2-2×10 door header: a 2-2×8 is allowed 5 ft 9 in. at 70 psf in the same column, short of a 6-ft opening. The deeper header is also why the door opening is 77-1/2 in. tall rather than closer to 80 in.
- Floor joists have a large margin, which also covers the tables’ dry-lumber assumption. Joist ends bear 1-1/2 in. on the outer skids (IRC R502.6 minimum).
- Skids are our adaptation. The IRC has no shed-skid table, so we used the deck beam table: the center skid carries about 7.3 ft of floor, so we read the 16-ft joist column and used 2×8 plies. The deck table doesn’t cover the wall, roof, and snow loads on the outer skids, so have your building department confirm the block spacing before you build. Nail the plies with two rows of 10d (3 x 0.128 in.) nails 16 in. apart along each edge (R507.5), and give each skid end at least 3 in. of bearing (R507.5.1). The block spacing passes the 2021 and 2024 editions of Table R507.5(1); we checked it against the lower 2021 values (5-4 (SP), 4-8 (DF-L/HF/SPF)), since many places still use the 2021 IRC.
- Floor load: 40 psf is the IRC’s live load for living areas and decks, not a vehicle rating. Park a riding mower with its wheels near a skid line, or have a pro size the floor for a tractor or a heavy shop.
Check these judgement calls with your building department. The skids, the 6:12 heel nailing, and the gable-end rafters above use our reading of the closest IRC tables, not an engineer’s design. Show your building department this section, and follow its answer if it differs.

Material list: how much lumber a 12×16 shed needs
Quantities include a spare rafter board. Buy extra 2x4s if you’re new to framing.
Foundation and floor
| Qty | Material |
|---|---|
| 6 | 2×8 x 16 ft treated, rated for ground contact (6 plies of 192 in. for three 2-ply skids) |
| 18 | solid concrete blocks, at least 8 x 16 in. (three rows of 6; see “Site and foundation”) |
| 18 | concrete pads or pavers, at least 16 x 16 in. (one under each block; required for this plan) |
| — | Crushed gravel for a 14 x 18 ft pad (about 3.1 cubic yards at 4 in. deep) and landscape fabric |
| 15 | 2×6 treated: 13 x 12 ft, 2 x 16 ft (2 rim joists of 192 in. and 13 floor joists of 141 in.) |
| 7 | 23/32 in. APA Rated Sturd-I-Floor panels, span rating 24 oc, tongue-and-groove, 4 ft x 8 ft (6 needed, plus 1 spare) |
| — | 4 (minimum) ground anchors with cable and clamps, sized for your soil by the anchor maker |
Wall framing
| Qty | Material |
|---|---|
| 66 | 2×4 x 8 ft (studs, jacks, sills, cripples, gable studs, ridge posts) |
| 6 | 2×4 x 16 ft (front and back wall plates) |
| 6 | 2×4 x 12 ft (gable-wall plates) |
| 1 | 2×10 x 14 ft (door header, 2 plies) |
| 1 | 2×6 x 10 ft (window headers, 4 plies of 27 in.) |
| — | 1/2 in. plywood scraps for header spacers (from the roof sheathing offcuts) |
Roof framing and roofing
| Qty | Material |
|---|---|
| 27 | 2×6 No. 2 x 10 ft (26 rafters, plus a spare board) |
| 11 | 2×6 No. 2 x 12 ft (ceiling joists) |
| 1 | 2×8 No. 2 x 16 ft (ridge board) |
| 4 | 1×4 x 8 ft (11 collar ties of 26 in.) |
| 10 | 15/32 in. or 1/2 in. APA Rated Sheathing, span rating 32/16, 4 ft x 8 ft (8 needed, plus 2 spares) |
| — | Roofing underlayment for about 250 sq ft plus laps |
| — | Drip edge, 8 pieces x 10 ft (about 63 linear ft of eaves and rakes, plus laps) |
| — | Architectural asphalt shingles, 9 bundles (GAF says 3 bundles of Timberline HDZ cover 98.4 sq ft; this roof is about 250 sq ft, plus cutting waste), plus starter strip shingles for about 63 linear ft and hip-and-ridge cap shingles for 16 ft of ridge, per the shingle maker |
| — | Roofing nails: IRC R905.2.5 calls for galvanized steel, stainless steel, aluminum, or copper roofing nails with a 12-gauge minimum shank and 3/8 in. minimum head, long enough to go through the sheathing (it’s thinner than 3/4 in.) |
| 26 | Simpson Strong-Tie H2.5A hurricane ties, plus 260 – 0.131 x 2-1/2 in. nails (or Simpson SD9212 screws) |
Siding, trim, doors, and windows
| Qty | Material |
|---|---|
| 18 | 4 ft x 8 ft panel siding sheets (this plan follows LP SmartSide Strand Substrate 76 Series panel instructions): 8 for the eave walls, 6 for the gable walls, 2 for the gable triangles, 2 for the door leaves |
| 2 | 1×8 exterior trim x 16 ft (fascia) |
| 4 | 1×6 exterior trim x 10 ft (rake boards) |
| 16 | 1×4 exterior trim x 8 ft (8 corner boards, door rails and braces, astragal, window trim) |
| — | Z-flashing, 5 pieces x 10 ft (gable joints, over the doors and windows) |
| 2 | clear polycarbonate sheets, 1/4 in., cut 26 x 26 in. (fixed windows); or shed windows whose rough opening fits the framing |
| 6 | heavy-duty exterior T-hinges or strap hinges, 2 barrel bolts for the fixed leaf, a hasp or gate latch, 2 door pulls |
| — | 1/4 in. hardware cloth, small roll (for the open rafter bays above the walls) |
Fasteners and finishing (nail sizes from IRC Table R602.3(1) unless noted; IRC R304.3.1 requires hot-dipped zinc-coated galvanized, stainless, silicon bronze, or copper fasteners in preservative-treated wood)
| Qty | Material |
|---|---|
| — | 16d common nails (3-1/2 x 0.162 in.), hot-dip galvanized for treated lumber, for framing and heel joints |
| — | 10d common nails (3 x 0.148 in.) for rafters, collar ties, and toenailing |
| — | 10d nails (3 x 0.128 in.), hot-dip galvanized, for nailing the skid plies together (IRC R507.5) |
| — | 8d common nails (2-1/2 x 0.131 in.) for the floor deck, roof sheathing, and ceiling joist toenails; hot-dip galvanized for toenailing joists to skids |
| — | Siding nails: 6d (0.113 in. shank) hot-dipped galvanized, long enough to go at least 1-1/2 in. into framing (LP’s minimum for 38 and 76 Series panels; not electroplated) |
| — | 1-5/8 in. exterior screws (trim, doors) |
| — | Exterior sealant (LP calls for ASTM C920, Class 25 minimum), exterior primer and paint |
Cut list
The full cut list is in the free PDF. Download the printable 12×16 shed plan (PDF) → It lists every part with its size, quantity, and notes.
Each rafter needs about 95-13/16 in. of board once you count the parallel plumb cuts at both ends, which leaves only about 3/16 in. on a 96-in. board, so buy 10-ft 2x6s (one rafter per board). Step 5 shows how to mark the pattern rafter; the PDF shows how the numbers are worked out.

How much does it cost to build a 12×16 shed?
Prices vary by region and week, so we don’t print a total. Price the material list locally and add delivery and permit fees.
Want more weekend projects? TedsWoodworking is a paid online plan collection, and the seller says it bundles over 16,000 plans. It isn’t made by Shed & Bench.
Affiliate link: we may earn a commission if you buy, at no extra cost to you. Affiliate disclosure.
Step 1: Build the skids and the floor
- Nail each pair of 192-in. 2x8s face to face with two rows of 10d nails, 16 in. apart, along each edge (IRC R507.5). Set the three skids on edge on their blocks, one under each rim and one centered, and level them.
- Mark both rims for joists at 16 in. on center: one flush at each end, then centered at 16, 32, 48 … 176 in.
- Stand the rims on edge 144 in. apart outside to outside, set the 141-in. joists on the marks, and end-nail through the rim into each joist with three 16d common nails (IRC Table R602.3(1), item 27).
- Square the frame (diagonals about 240 in.).
- Set the frame on the skids. Toenail each joist to each skid with three 8d common nails (item 22). Attach the ground anchors.
- Lay the deck with the long edges across the joists in three rows: two full sheets in the outer rows and 48 + 96 + 48 in. in the middle, so the end joints land on joists and don’t line up. Nail with 8d common nails 6 in. apart at the panel edges and 12 in. at the intermediate joists (item 38). T&G panels cover a little under 48 in., so measure the rows; if they come up short, rip a filler strip.
Step 2: Frame the front wall with the double-door opening
- Cut the plates (192, 192, and 185 in.), 12 studs at 85-1/4 in., four jack studs at 76 in., two 78-in. 2x10s, and a 9-1/4 x 78 in. plywood spacer.
- Build the header: sandwich the spacer between the 2x10s and nail with 16d common nails 16 in. apart along each edge (item 10).
- Mark the plates: end studs flush at each end; common studs centered at 16, 32, 48, 144, 160, and 176 in.; two king studs on each side of the door, at 54 to 57 and 135 to 138 in.; and two jacks inside the inner kings on each side (57 to 60 and 132 to 135 in.), leaving a 72-in. opening from 60 to 132 in.
- Nail the end, common, and king studs between the bottom plate and the first top plate with two 16d common end nails per joint (item 17). Face-nail each pair of kings together, each pair of jacks together, and the jacks to the inner king, with 16d common nails 24 in. apart (item 8).
- Set the header on the jacks, tight under the top plate, so the top plate braces the header’s top (Table R602.7(1) footnote f). That makes the opening 77-1/2 in. tall. End-nail through the inner king into each end of the header with three 16d common nails (item 12).
- Square the wall, raise it onto the front edge of the deck with your helpers, and nail the bottom plate down with 16d common nails 16 in. apart (item 15), except inside the door opening. Brace it plumb.

Step 3: Frame the back wall with the window openings
- Cut the plates, 13 studs at 85-1/4 in., four jacks at 79-3/4 in., four 27-in. 2×6 header pieces with two 5-1/2 x 27 in. spacers, two 24-in. flat sills, and four cripples at 54-1/4 in.
- Mark the plates: end studs flush; common studs centered at 16, 32, 48, 96, 144, 160, and 176 in.; kings at 57 to 58-1/2, 85-1/2 to 87, 105 to 106-1/2, and 133-1/2 to 135 in.; jacks inside them; cripples centered at 64, 80, 112, and 128 in.
- Assemble as in Step 2, with one jack each side of each window. Nail each sill flat on its cripples between the jacks, so each rough opening is 24 x 24 in. (60 to 84 and 108 to 132 in. along the wall), with its bottom 57-1/4 in. above the deck. If you buy shed windows, frame their rough openings instead; the 2-2×6 header covers openings up to 4 ft 6 in., but an opening over 4 ft needs a second king stud each side.
- Raise the wall onto the back edge of the deck, nail it down, and brace it plumb.

Step 4: Frame the gable walls and tie the corners
- For each gable wall, cut the bottom and top plates at 137 in., the upper top plate at 144 in., and 13 studs at 85-1/4 in.
- Lay out studs at the ends and every 12 in. measured from the front corner of the building (12, 24, 36, 48, 60, 72, 84, 96, 108, 120, and 132 in.). That puts studs under the siding joints at 48 and 96 in. and under the ridge post at 72 in.
- Assemble with two 16d end nails per joint, raise each wall between the eave walls, and nail the bottom plate down.
- Face-nail the end studs to the eave-wall end studs with 16d common nails 16 in. apart (item 9).
- Nail the 144-in. upper top plate on top so it laps onto the eave walls’ lower top plates, with 16d common nails 16 in. apart (item 13) and two 16d nails at each corner lap (item 18).
- Plumb, square (diagonals within about 1/4 in.), and brace the walls.

Step 5: Cut a pattern rafter and set the ridge
- Mark the pattern. On a straight 2×6, mark a 6-in-12 plumb line at the top end (ridge cut). Measure 79-11/16 in. along the top edge and draw the heel plumb line. Draw the birdsmouth: a 3-1/2 in. level seat and a plumb cut about 1-3/4 in. deep. Measure another 13-7/16 in. along the top edge and mark the plumb tail cut.
- Test it. With a 2×8 scrap as a stand-in ridge, its bottom edge should meet the inside corner of the top plate and its top edge the top of the ridge. Check both ends and the middle, then cut 26 rafters in total.
- Lay out the top plates: end rafters flush with each end, the rest centered at 16, 32 … 176 in. (13 per side).
- Raise the ridge. Toenail a 32-3/4 in. 2×4 post to the gable top plate at the center of each gable wall. With two helpers on ladders, set the 192-in. 2×8 ridge on the posts and nail it down. Add a temporary 2×4 post at mid-length to hold the 16-ft ridge straight until the first rafter pairs are in.
- Set the rafters in opposing pairs so the ridge stays straight. At the ridge, use three 10d common toenails or two 16d common end nails per rafter (item 7). At the plates, toenail with two 10d common nails on one side (item 6 and its footnote, since each interior rafter gets a ceiling joist beside it; the four end rafters have no ceiling joist, so give each one a third 10d toenail on the opposite side); the ceiling joist gets its own toenails in Step 6.
Step 6: Ceiling joists, heel nailing, collar ties, and hurricane ties
- Clip the ceiling joists. At each end of the 11 ceiling joists (144-in. 2x6s), cut a 6-in-12 taper about 1-1/8 in. deep so the corner stays under the roof. IRC R802.7.1.2 limits ceiling joist taper cuts to one-fourth of the depth (1-3/8 in. for a 2×6).
- Set one beside each interior rafter pair, on both eave-wall plates. Toenail each end to the plate with three 8d common nails (item 2).
- Nail the heel joints: five 16d common nails through the ceiling joist into the rafter at each end (Table R802.5.2(1); see the sizing section).
- Collar ties: nail a 26-in. 1×4 across each interior pair, bottom edge 29 in. above the top of the plates, with three 10d common nails at each end (item 5). Once the collar ties and a few sheathing panels are on, you can remove the temporary ridge post.
- Hurricane ties: fasten a Simpson H2.5A at every rafter at both walls (26 total), on the inside face of the wall, on the side of each rafter away from its ceiling joist, with five 0.131 x 2-1/2 in. nails into the rafter and five into the plates. Simpson’s evaluation report allows the inside face (ICC-ES ESR-2613, Table 1, footnote 3), and it keeps the ties clear of the siding notches in Step 8.
- Gable studs: cut each stud to fit between the gable top plate and the end rafter (long points 4-5/8, 10-5/8, 16-5/8, 22-5/8, and 28-5/8 in.), and toenail with four 8d common nails at each end (item 17).
Wind and uplift
IRC Table R802.11 lists the uplift force on each rafter-to-wall connection. For rafters at 16 in. on center, a roof pitch of 5:12 or more, and a 12-ft span (this roof’s width), the forces are:
| Wind speed (ultimate) | Exposure B | Exposure C |
|---|---|---|
| 110 mph | 57 lb | 117 lb |
| 120 mph | 85 lb | 157 lb |
| 130 mph | 117 lb | 201 lb |
| 140 mph | 150 lb | 247 lb |
Simpson’s catalog lists an allowable uplift of 615 lb per H2.5A tie in spruce-pine-fir/hem-fir (700 lb in Douglas fir/Southern pine), far above any of these. Those are manufacturer ratings, not code values. Simpson says its SD9212 screws give the same load; ordinary deck or drywall screws are not a substitute. The two king studs at the door assume wind below 140 mph in Exposure B or 130 mph in Exposure C (Table R602.7.5); above that, or in Exposure D, ask your building department.
LP says single nailing of its 76 Series panels meets wall bracing requirements, which is why this plan uses 76 Series.
Step 7: Roof sheathing, drip edge, and shingles
- Sheathing. A 32/16 panel may span 28 in. without edge support (IRC Table R503.2.1.1(1)). Start at the eave with full sheets flush with the tails, strength axis across the rafters: two 96-in. sheets per side. Rip the top course (about 45-3/4 in.) to meet at the ridge, laid as a 48-in. piece, a full length, and a 48-in. piece, so its end joints don’t line up with the one below. End joints land on rafters. APA recommends a 1/8 in. gap at panel edges and ends unless the panel maker says otherwise.
- Nail it with 8d common nails (2-1/2 x 0.131 in.) 6 in. apart at the edges and 6 in. at every intermediate rafter (IRC Table R602.3(1), item 31). If your design wind speed is over 130 mph in Exposure B or over 110 mph in Exposure C, space the nails 4 in. apart at every rafter instead. On a roof this size, the table’s 48-in. edge and ridge zones cover the whole roof. Where your framing’s specific gravity is below 0.42, use RSRS-03 ring-shank nails (same footnotes).
- Fascia. Snap a line across the tails, trim any that stick out, and nail on the 1×8 fascia (it covers the 6-1/8 in. plumb cut).
- Drip edge and underlayment. IRC R905.2.8.5 requires drip edge at eaves and rakes of shingle roofs, lapped at least 2 in., extending at least 1/4 in. below the sheathing and 2 in. onto the deck, fastened at most 12 in. apart. Put the underlayment over the drip edge at the eaves and under it at the rakes. At 6 in 12, one layer of underlayment meets IRC R905.2.2; double underlayment is only required below 4 in 12.
- Shingles. Follow the shingle maker’s instructions; GAF’s Timberline instructions call for starter strips at eaves and rakes, a 5-5/8 in. exposure, and four nails per shingle (the IRC R905.2.6 minimum). Cap the ridge.
Step 8: Siding, gable triangles, and trim
LP’s panel instructions call for studs at 16 in. on center at most; nails 6 in. apart at panel edges and 12 in. in the field, 3/8 in. from the edge and 1-1/2 in. into framing; 1/8 in. gaps at vertical joints and 3/16 in. at trim, sealed; 6 in. above grade and 1 in. above roofing; and primed, painted cut edges.
- Notch the eave-wall panels first. Each rafter tail hangs about 2-1/16 in. below the top of the wall at the siding face, so a full-height panel would hit it. Mark the rafter positions on the top edge of each front and back panel and cut a notch about 1-5/8 in. wide and 2-1/8 in. deep at each one, then test-fit and trim. Seal the small gaps around the tails with exterior sealant, or cover them with the hardware cloth below.
- Eave walls. Hang four 48 x 96 in. panels per wall, from the bottom of the rim to the top of the wall.
- Cut the door opening from inside with a jigsaw, along the jacks and the underside of the header, and saw out the bottom plate. Cut the window openings the same way.
- Gable walls. Hang three full panels per wall, flush with the outside of the front and back walls. Their joints land on the studs at 48 and 96 in.
- Gable triangles. Cut each gable triangle from one sheet, in four pieces (48 and 24 in. wide on each side of the ridge), with sloped tops that meet the underside of the roof sheathing. LP shows a butt-and-flash horizontal joint: a 3/8 in. minimum gap over sloped flashing with a 4-in. vertical leg, backed by framing (here, the gable top plate). Install Z-flashing on top of the lower panels before hanging the triangles.
- Trim. Add 1×4 corner boards and 1×6 rake boards. LP says trim must be thick enough that the siding doesn’t stick out past it.
- Close the eaves. Staple 1/4 in. hardware cloth over the open spaces between rafters above the eave walls.

Step 9: Build the double doors and the window
- Cut two 36-7/8 x 80 in. leaves from siding panels.
- Screw 33-7/8-in. 1×4 rails across the inside top and bottom of each leaf (inset 1-1/2 in. from the sides, 4 in. from the ends) and a diagonal brace between them, low end on the hinge side.
- Hang each leaf with three hinges into the king and jack studs: 1 in. of overlap at the outer edges, tops 1-1/2 in. above the opening, a 1/4 in. gap between leaves.
- Screw a 1×4 astragal down the outside edge of the active leaf to cover the gap. Add barrel bolts at the top and bottom of the fixed leaf, a latch, and pulls.
- Windows. Bed each polycarbonate sheet over its opening in exterior sealant and frame its edges with 1×4 trim. Fasten it as the sheet maker specifies. Add Z-flashing over the window trim and the door head trim; LP says all openings must be properly sealed or flashed.

Finishing your 12×16 shed
- Prime and paint the siding, trim, and every cut edge. Seal trim joints, but leave the bottom edges of the siding open to drain.
- Lay 1/2 in. plywood on the ceiling joists for light storage only (IRC Table R802.5.1(2), attics with limited storage). It isn’t a loft for people.
- Keep at least 6 in. between the siding and the ground all the way around.
Setting up the inside? Two of the free projects in Your First 10 Weekend Builds are made for a new shed: a Bracketed Wall Shelf for the studs and a Slatted Storage Crate for the floor, plus 8 more beginner builds, each with a materials list. Get the free guide →
Maintenance
Each spring and fall, check for loose shingles or trim, open sealant joints, and peeling paint. After big storms, check that the shed hasn’t moved and the anchor cables are tight (Minute Man recommends checking tension periodically where frost is heavy). Keep soil, mulch, and snow off the siding, and oil the hinges and latch once a year.
Build vs. buy a 12×16 shed
A kit or a pre-built shed is faster and needs fewer tools, but you’re limited to the seller’s materials and options, and you still prepare the site, meet local rules, and anchor it; a pre-built 12×16 also needs clear delivery access. Price this material list locally and compare it with a kit’s price, contents, and delivery. We haven’t drawn a 12×16 lean-to; at a 12-ft span every check changes.
Next project? Our picnic table plans and chicken coop plans come with full cut lists and printable PDFs too.
Beyond sheds. If you also want ideas for smaller projects, like benches, planters, and shop furniture, TedsWoodworking is a paid plan library. The seller says it bundles over 16,000 plans (the seller’s count; one critic disputes it, see our review). It isn’t made by Shed & Bench, and for a structure like a shed, we’d stick with a plan that shows how it was sized, like this one.
Disclosure: the link below is an affiliate link. If you buy through it, Shed & Bench may earn a commission at no extra cost to you. Affiliate disclosure.
Get the free guide: Your First 10 Weekend Builds
Ten simple, original beginner projects you can build with a drill, a saw, and a couple of clamps, each with a materials list. Sent to your inbox. Unsubscribe anytime. Some emails include clearly labeled affiliate recommendations. See our Privacy Policy.
This form is protected by reCAPTCHA, and the Google Privacy Policy and Terms of Service apply.
FAQs about 12×16 shed plans
Do I need a permit for a 12×16 shed?
Probably. At 192 sq ft it’s under the 2024 IRC’s 200-sq-ft exemption but over the 2024 IBC’s 120-sq-ft one, many cities set their own limit, and at the roof line it’s about 224 sq ft. Ask your building department.
How much lumber do I need for a 12×16 shed?
For this plan: 78 2x4s (66 of them 8 ft long, the rest longer boards for the wall plates); 27 2×6 x 10 ft for rafters and 11 2×6 x 12 ft for ceiling joists; a 2×8 x 16 ft ridge; 1 2×10 x 14 ft for the door header; 1 2×6 x 10 ft for the window headers; and 21 treated boards for the skids and floor. Add 7 floor panels, 10 roof sheathing panels, and 18 siding panels. The full list is above.
What size rafters does a 12×16 shed need?
In this plan, 2×6 No. 2 at 16 in. on center: IRC Table R802.4.1(7) allows at least 7 ft 5 in. at 70 psf ground snow, and this roof spans about 5 ft 11-1/4 in.
What size header do I need for a 6-ft shed door?
In this plan, a 2-2×10 with two jacks and two kings each side. IRC Table R602.7(1) allows a 2-2×10 6 ft 9 in. at 70 psf in a 12-ft-wide building (a 2-2×8 falls short), and Table R602.7.5 calls for two kings at each end of a 6-ft header below 140 mph Exposure B or 130 mph Exposure C.
Is there a free PDF of these 12×16 shed plans?
Yes, with no email required. It has the materials list, the full cut list, key steps, and all nine diagrams.
Sources
The IRC and IBC text was checked against ICC’s free online viewer (2024 IRC, edition IRC2024V2.0; 2024 IBC, edition IBC2024V1.0). The code links below go straight to ICC’s chapter pages.
- IRC 2024, Chapter 1 (R105.2 work exempt from permit): https://codes.iccsafe.org/content/IRC2024V2.0/chapter-1-scope-and-administration
- IBC 2024, Chapter 1 (Section 105.2 work exempt from permit): https://codes.iccsafe.org/content/IBC2024V1.0/chapter-1-scope-and-administration
- IRC 2024, Chapter 3 (Table R301.2; R304.3.1 fasteners in treated wood): https://codes.iccsafe.org/content/IRC2024V2.0/chapter-3-building-planning
- IRC 2024, Chapter 4 (Table R401.4.1 soil bearing; R403, R403.1.4.1 frost protection and Exception 1): https://codes.iccsafe.org/content/IRC2024V2.0/chapter-4-foundations
- IRC 2024, Chapter 5 (Table R502.3.1(2) floor joists; R502.6 bearing; Table R503.2.1.1(1) panel spans; R507.5, Table R507.5(1), R507.5.1 deck beams): https://codes.iccsafe.org/content/IRC2024V2.0/chapter-5-floors
- IRC 2024, Chapter 6 (Table R602.3(1) fastening; Table R602.3(5) studs; Table R602.7(1) headers; R602.7.5 and Table R602.7.5 king studs): https://codes.iccsafe.org/content/IRC2024V2.0/chapter-6-wall-construction
- IRC 2024, Chapter 8 (R802.2, R802.3, R802.4.1 and Table R802.4.1(7), R802.4.6 collar ties, Table R802.5.1(2), R802.5.2 and Table R802.5.2(1), R802.7.1.1, R802.7.1.2, Table R802.11): https://codes.iccsafe.org/content/IRC2024V2.0/chapter-8-roof-ceiling-construction
- IRC 2024, Chapter 9 (R905.2.2, R905.2.5, R905.2.6, R905.2.8.5): https://codes.iccsafe.org/content/IRC2024V2.0/chapter-9-roof-assemblies
- IRC 2021, Chapter 5 (Table R507.5(1) deck beams, 2021 values; read in UpCodes’ New Jersey IRC 2021 viewer, which doesn’t amend this table): https://up.codes/viewer/new_jersey/irc-2021/chapter/5/floors
- AWC Span Options Calculator: https://awc.org/resources/span-options-calculator-for-wood-joists-and-rafters/
- APA, span ratings explained: https://www.apawood.org/for-builders ; APA E30 roof excerpt (hosted by Georgia-Pacific): https://www.buildgp.com/wp-content/uploads/2022/06/APA-Engineered-Wood-Construction-Guide-Roofs-E30-2020.pdf
- Simpson Strong-Tie Wood Construction Connectors catalog, page 277 (H2.5A manufacturer ratings, not code values; distributor-hosted copy): https://palmerdonavin.cld.bz/Simpson-Strong-Tie-Wood-Construction-Connectors/277/
- ICC-ES ESR-2613, Simpson Strong-Tie hurricane ties including H2.5A (allowable loads; Table 1, footnote 3 for inside-face installation): https://icc-es.org/report-listing/esr-2613/
- GAF Timberline installation instructions: https://documents.gaf.com/installation-instructions-&-guides/timberline-layerlock-installation-instructions-trilingual-restl622.pdf
- LP SmartSide Strand Substrate panel siding application instructions: https://cdn2.hubspot.net/hubfs/2998704/pdfs/product-pdfs/siding-and-trim/lp-smart-side/lp-smartside-strand-substrate-panel-siding-application-instructions.pdf
- Suncast, Wood Shed Foundation Preparation: https://suncast.com/media/blfa_files/A01B02.pdf
- American Earth Anchors, Shed Anchor Installation: https://americanearthanchors.com/content/Application%20Specific%20PDF/Shed%20Anchor%20Installation%20-%20AEA.pdf
- Minute Man Products, General Guidelines for Anchoring Sheds (manufacturer recommendations, not code values): https://minutemanproducts.com/minute-man-products/docs/anchoring-sheds-guidelines.pdf
All dimensions, cut lengths, and board counts on this page were calculated and cross-checked in code by Shed & Bench.